Lochinvar Heat Pump 80-Gallon (HPPA080KD 2) vs Noritz ME120HPT-CN 80-Gallon

The Lochinvar Heat Pump 80-Gallon (HPPA080KD 2) is the more efficient unit: UEF 3.88 versus 3.38 — about 13% less energy for the same hot water. At national average rates that works out to about $217/year for the Lochinvar Heat Pump 80-Gallon (HPPA080KD 2) against $249/year for the Noritz ME120HPT-CN 80-Gallon — a $32 annual difference. The Noritz ME120HPT-CN 80-Gallon delivers more hot water in the peak hour (105 gal first-hour rating vs 95 gal). Only the Lochinvar Heat Pump 80-Gallon (HPPA080KD 2) is connected-capable (app control, utility programs).

Lochinvar Heat Pump 80-Gallon (HPPA080KD 2) Noritz ME120HPT-CN 80-Gallon
Uniform Energy Factor (UEF) 3.88 3.38
Fuel Electric Electric
First-hour rating 95 gal 105 gal
Rated storage volume 81 gal 109 gal
Draw pattern High High
Annual electricity use 1279 kWh/yr 1467 kWh/yr
Heat pump type 240 Volt Integrated HPWH 240 Volt Integrated HPWH
Input voltage 240 240
Max current draw 22 A 23 A
Recovery efficiency 428 % 355 %
Smart / connected capable Yes No
Refrigerant (GWP) R-134a (GWP:1430) R-134a (GWP:1430)
Compressor low-temp cutoff 37 °F 35 °F
Height 69 in 84.5 in
Diameter 27 in 30 in
ENERGY STAR certified Yes Yes

Frequently asked questions

Which costs less to run, the Lochinvar Heat Pump 80-Gallon (HPPA080KD 2) or the Noritz ME120HPT-CN 80-Gallon?

The Lochinvar Heat Pump 80-Gallon (HPPA080KD 2): about $217/year versus $249/year for the Noritz ME120HPT-CN 80-Gallon at national average rates — a $32 annual difference.

Are the Lochinvar Heat Pump 80-Gallon (HPPA080KD 2) and Noritz ME120HPT-CN 80-Gallon both ENERGY STAR certified?

Yes — every water heater in this database is drawn from the U.S. EPA ENERGY STAR certified water heater datasets.